STARTING AND RUNNING CHECKS AND STOPPING OF AIR COMPRESSOR
STARTING PROCEDURE
- check the air bottle pressure and drain the air bottle for any condensate moisture.
- Open air bottle filling valve.
- Open compressor air discharge valve,
- Check compressor sump oil level,
- Open compressor air cooler cooling water inlet and outlet valves,
- Purge out cooling water area -jacket etc,
- Open drain valve of each stage,
- Crank the compressor by hand a couple of times.
- Make sure compressor body is free from any other foreign materials,
- Start the compressor,
RUNNING CHECKS:
- close the air cooler air side stages drain valves, starting from 1st stage.
- Check compressor lub oil pressure and cooling water pressure,
- Drain each stage cooler and air bottle at regular intervals of 5 mints.
- Check crankcase and all stages coolers for over heating,
- Check for any abnormal sounds,
- Check the air pressure and air temperature of air receiver and every stage of compressor.
STOPPING PROCEDURE:
- when air bottle attained the required pressure
- Open the air cooler drain valves (starting from 3rd stage to 1st stage)
- Stop the compressor,
- Close compressor outlet valve,
- Close air bottle inlet valve,.
- Drain air bottle to remove any condensate,
- Shut the cooling water inlet and outlet valves, after air compressor has cooled down,
- Check all valves are in their correct position.