Mariners Voice is a journal-style blog created by and for seafarers. It shares real-life stories, professional experiences, safety tips, industry updates, and reflections on the unique lifestyle of maritime workers. Whether you're a seasoned sailor, a cadet, or someone curious about life at sea, this blog offers authentic content straight from the deck to the digital world.
EPIRB EMERGENCY POSITION INDICATING RADIO BEACION
INDICATOR DIAGRAM
indicator diagram
- At the same time it will indicate pressure and the position of piston.
- To indicate the power developed in the system (cylinder).
- To indicate the pressure maximum (Pmax) and compression pressure
- To find the exhaust and scavenging condition
- To evaluate the combustion process.
- Draw card
- Power card
- Compression card
- Light spring diagram
- Its used to find the Pmax & Pcom accurately
- With this draw card we can find the ignition delay,fuel pump timing and after burning and the loss of compression.
- Its 90° out off phase with piston movement.
- Its used to find the indictor power.
- And to find the peak pressure and compression pressure.
- Its in-phase with piston with fuel on.
- It can be find by planimeter.
- Its used to find the compression pressure.
- Ans the cylinder thickness.
- Its in-phase cut off fuel and reduce rpm.
- Its used to find the pressure variation in the cylinder. With respect to scavenge and exhaust manifold.
- It is in-phase with light spring in fuel on .
- It will show the chocks in scavenge manifold and exhaust valve chocks and less air.
- 4 stroke piston moves 2 times to TDC in one cycle. So we can't able to take.
FOAMING / PRIMING AND ITS EFFECTS IN BOILER
FOAMING
Formation of thick layer of steam bubbles.
PRIMING
Its the condition of large amount of water carried over alone with the steam
EFFECT OF FOAMING AND PRIMING
- water hammering
- Contamination
- Scale formation
- Fluctuation in water level
2/03/2021 MMD ORAL QUESTIONS ANSWER FUNCTION 3
BOILER ALARMS AND TRIPS
- Low water level alarm - ⏰ Alarm
- Low low water level alarm - ⏰ Alarm / Trip
- High water level alarm - ⏰ Alarm
- High High water level - ⏰ Alarm / Trip
- Low fuel oil pressure - ⏰ Alarm
- Low steam pressure - ⏰ Alarm
- High steam pressure - ⏰ Alarm / Trip
- Low fuel oil temperature - ⏰ Alarm
- High fuel oil temperature - ⏰ Alarm
- Flame failure - ⏰ Alarm / Trip
- Burner not in starting fire position - ⏰ Alarm / Trip
- Low combustion Air pressure - ⏰ Alarm / Trip
SPRINKLER SYSTEM
Every ship of 2000Gt and above ,and machinery space of 500m3 and above should have fixed fire fighting System.
Regulation for SPRINKLER SYSTEM
- It must have two sources of power supply for seawater pump and fresh water pump., And fire detection,fire alarms.
- In Accommodation sprinkler will come to action on 69 degree to 79 degree .
- Sprinkler should be corrosive resistance.
- Each head fixed not more than 200 SPRINKLERS.
- Each should covers 16 m3 area.
- 2m from the vertical wall and shall 4 m distance for each sprinkler.
- Each sprinkler capable of 100lit/min discharge @4.8 bar pressure
- Each section of sprinkler should have isolation valve.
- A gauging indication should be provided dor each section stop valve .
- A test valve is provided each section near the stop valve .
- Paint room sprinkler shall 5lit/mint connected with fire main pump of ship.
LOCATION
Fitted with no risk of fire area. Such as CO2 room, public toilet. Etc..