AIR COMPRESSOR MANUAL STARTING PROCEDURE
Air compressor starting procedure manually.
- Change over the switch to manual position on the switch board.
- Check the L.O sump level and condition.
- Open the moisture drain valve.
- Open the compressor discharge valve and charging valve of air bottle.
- Open cooling water system valves.
- Turn compressor flywheel by hand (one turn)
- Now Start the motor, after that draining the moisture and shut the drain valve.
- Check the motor ampere consumed.
- Check the pressure gauge readings.
- Frequently drain the moistures.
- Once the charging full, open drain valve and stop the compressor.