CLASSIFICATION OF BULKHEADS MEO CLASS 4
CLASS A
- FORMING AS A BULKHEADS DECKS
- MADE OF STEEL OR OTHER SUITABLE MATERIAL.
- ONE HOUR STANDARD FIRE TEST FOR PREVENT THE PASSAGE OF SMOKE AND FLAME.
- INSULATED BY NON COMBUSTIBLE MATERIAL.
- MINIMUM TEMPERATURE ON UNEXPLORED SIDE SHOULD NOT RISE ABOVE 139° C.
- POINT TEMPERATURE ABOVE 180°C
- A60 - 60 MINUTES
- A30 - 30 MINUTES
- A15 - 15 MINUTES
- A0 - 0 MINUTES
CLASS B
- FORMING BY A BULKHEADS DECKS AND CEILING AND LINING.
- 30 HOURS STANDARD FIRE TEST OF FLAME
- UNEXPLORED TEMPERATURE 139°C ABOVE ORIGINAL
- POINT TEMPERATURE RISE MORE THAN 225°C
- NON COMBUSTIBLE MATERIAL
- B15 - 15 MINUTES
- B0 - 0 MINUTES
CLASS C
- CONSTRUCTED AS A DECK
- APPROVED BY SOLAS AND CLASSIFICATION SOCIETY AS A NON COMBUSTIBLE MATERIAL.
- NOT REQUIRED TO STANDARD FIRE TEST.